跳到主要内容

SenseCAP CO2 Sensor

NDIR CO2 Sensor

Product Description

This is a digital CO2 concentration sensor based on NDIR (nondispersive infrared), which can continuously collect and calculate the CO2 concentration in the air per unit volume and output in the form of a universal interface. It's designed to adopt PTFE film combined with a protective enclosure, improving its breathable performance. It is more accurate, stable, reliable, low-power consumption, and user-friendly. It compacts in size and can be easily integrated into various application scenarios.

This digital NDIR CO2 concentration sensor supports MODBUS RS485 serial communications, SDI-12 communication protocols, and is compatible with the wide power supply voltage of 5-16V. It has a built-in calibration functionality and can be widely applied in both indoor and outdoor environments. This product also adopts both single-air-chamber and double-channel.

Features

  • High performance: high accuracy, fast response, and superior stability
  • support MODBUS RS485 and SDI-12
  • Compact size, best performance-to-price ratio
  • User-friendly: fully-calibrated, easy to install and integrate
  • Wide-range Power Supply: 5V ~ 16V
  • Wide Range & High Accuracy: 400ppm ~ 5,000 ppm, ± (50ppm+5%*MV)

Applications

Applications

  • Smart Agriculture
  • Smart Cities
  • Building ventilation systems
  • Industry ventilation systems
  • Airport, train station, shopping mall, home, office, classroom, and others
  • public places for air quality measurement and indication
  • Lab, warehouse, and other places to monitor CO2 level

Specifications

CO2
Range400~5000 ppm
Accuracy± (50ppm+5%*MV)(in 400~3000ppm)
Resolution1 ppm
General Parameters
Product ModelSOLO CO2 5000
InterfaceRS-485
ProtocolMODBUS-RTU RS485/ MODBUS-ASCII RS485/ SDI-12 (v1.4)
Response Time (T90)<5 minutes for 90% step change typical
IP RatingIPx5
(the PTFE filter is not waterproof)
Operating Temperature-10 ~ +50 °C
Operating Humidity0 ~ 85% (non-condensing)
Cable Length2 meters
Probe Dimensions110* 50 * 35 mm
Device Weight300g
MODBUS RS-485
Power Supply5V ~ 16V
Current ConsumptionVin=16V; 22mA (typical)
Vin=12V; 28mA (typical)
Vin=9V; 34mA (typical)
Vin=5V; 57mA (typical)
Warm-up Time120s (typical)
Scan Interval1s
Poll Rate1Hz
Response Time≤ 4ms
SDI-12
Power Supply5V ~ 16V
Current Consumption
(Sleep Mode)
Vin=16V; 28mA (typical)
Vin=12V; 29mA (typical)
Vin=9V; 30mA (typical)
Vin=5V; 35mA (typical)
Current Consumption
(Active Mode)
Vin=16V; 20mA (typical)
Vin=12V; 27mA (typical)
Vin=9V; 33mA (typical)
Vin=5V; 55mA (typical)
Warm-up Time15ms
Scan Interval120s (typical)